This cable is suitable for residential buildings, kitchens, lighting service rooms or portable lighting equipment. Due to its special insulation and sheath compound, these cables are adapted to kitchens and heating, and are used in areas with higher temperatures (such as lighting systems) without contact with heated parts and radiation. It is not suitable for outdoor use, cannot be used in industrial and agricultural buildings or non-domestic portable tools, the maximum conductor temperature in normal use: 90 ° C. When used at high temperatures, skin contact must be avoided.
$0.00
Cable parameter:
TUV,CE
TUV,CE
CE
CE
  • H03V2V2-F      H03V2V2H2-F
  • H03V2V2-F      H03V2V2H2-F

Description

Application and description

This cable is suitable for residential buildings, kitchens, lighting service rooms or portable lighting equipment.
Due to its special insulation and sheath compound, these cables are adapted to kitchens and heating, and are
used in areas with higher temperatures (such as lighting systems) without contact with heated parts and radiation.
It is not suitable for outdoor use, cannot be used in industrial and agricultural buildings or non-domestic portable
tools, the maximum conductor temperature in normal use: 90 ° C. When used at high temperatures, skin contact
must be avoided.
                                                                                                                                                                                    

Standards and certifications

CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), EN50265-2-1
                                                                                                                                                                                    

Cable construction

- Flexible bare copper conductor

- Complies with DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383 standards

- PVC insulation T13 complies with VDE-0281 part 1

- Color coding complies with VDE-0293-308

- PVC outer sheath TM3
                                                                                                                                                                                    

Technical characteristics

- Operating voltage: 300/300 V

- Test voltage: 3000 V

- Dynamic bending radius: 15 x Ø

- Static bending radius: 4 x Ø

- Operating temperature during application: +5º C to +90º C

- Flame retardant: IEC 60332.1

- Insulation resistance: 20 MΩ x km
                                                                                                                                                                                    

Cable parameters:

Number of cores x conductor cross-sectional area

# x mm²

Nominal insulation thickness mm

Nominal outer diameter mm

Nominal copper weight kg/km

Nominal cable weight kg/km

Number of cores x conductor cross-sectional area

# x mm²

H03V2V2-F

2 x 0.50

0.5

0.6

5

9.6

38

3 x 0.50

0.5

0.6

5.4

14.4

45

4 x 0.50

0.5

0.6

5.8

19.2

55

2 x 0.75

0.5

0.6

5.5

14.4

46

3 x 0.75

0.5

0.6

6

21.6

59

4 x 0.75

0.5

0.6

6.5

28.8

72

H03V2V2H2-F

2 x 0.50

0.5

0.6

3.2 x 5.2

9.7

32

2 x 0.75

0.5

0.3

3.4 x 5.6

14.4

35